1.
Chinese Journal of Radiological Medicine and Protection ; (12): 659-664, 2021.
Article in Chinese | WPRIM | ID: wpr-910373

ABSTRACT

Objective:To study the effects of gantry acceleration limitations of a linear accelerator (linac) on the dosimetry of volumetric modulated arc therapy (VMAT) plans, machine efficiency, and dose verification result of VMAT plans and to explore the optimal selection of gantry motion models in the Pinnacle treatment planning system.Methods:Ten cases of nasopharyngeal carcinoma, non-small cell lung cancer, sigmoid adenocarcinoma with retroperitoneal lymph node metastasis, and invasive ductal carcinoma of the breast were each selected for this study. Then two models were set up in the Pinnacle v9.10 treatment planning system, namely the one allowing gantry acceleration and the one limiting gantry acceleration. The same field arrangement, optimized target parameters, and optimized weights of VMAT plans were adopted in the two models, in order to analyze the dosimetric variations in targets and organs at risk (OARs) and compare the differences in treatment time and gamma passing rates.Results:The treatment time of the enrolled patients under the model allowing gantry acceleration was significantly lower than that of the patients under the model limiting gantry acceleration was adopted ( t=-6.751, -0.209, -19.523, -28.999; P< 0.05) and decreased by 15.27%, 18.07%, 19.71%, and 28.75%, respectively. Meanwhile, the conformity and uniformity of target areas were affected, while there was no statistical significance in the gamma passing rates in the validation of VMAT plans ( P>0.05). For the cases of nasopharyngeal carcinoma (NPC), the maximum dose to brainstem PRV increased by 1.25%. For the cases of lung cancer, the maximum dose to the spinal cord and lung V20 increased by 1.19% and 1.21%, respectively, while lung V5 decreased by 1.21%. For the cases of sigmoid adenocarcinoma with retroperitoneal lymph node metastasis, the mean doses to bilateral kidneys, livers, small intestine, and colon all increased. For the cases of breast cancer, lung V10 on the opposite side of cancer increased by 1.66% and the mean dose to the lungs on the same side of cancer decreased by 7.45%. Conclusions:The model allowing gantry acceleration allows the treatment time to be significantly shortened and the treatment efficiency improved. Although this model had the shortcomings such as affecting the conformity and uniformity of target areas to a certain extent and increasing the doses to some OARs, clinical requirements for dosimetry were still met. Therefore, it is recommended to use the model allowing gantry acceleration in the Pinnacle planning system.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 386-389, 2012.
Article in Chinese | WPRIM | ID: wpr-427039

ABSTRACT

Objective To investigate the dosimetric influence of pure carbon fiber treatment tabletop of Elekta Precise new linear accelerator in radiotherapy.Methods Surface-axis distance (SAD) technology was employed for the measurement.Two groups of fields were set and both of them were SAD opposed portals ( one of them went through the tabletop,while the other did not).A PTW electrometer and a 0.6 cm3 Farmer ionization chamber were utilized for comparison measurement.Then dose attenuation of the main table board,extended body board,the extended board for head,neck and shoulders,and the joints of these boards were calculated.Results Under the energy of 6 MV,the dose attenuations of the following locations were:1.4% - 7.2% at the main treatment table board; 2.8% - 38.7%,1.4% -30.1%,1.5% -20.8% and 1.4% - 11.2%,respectively at distances of 1,4,7 and 8 cm from the joint of the main table board ;0.5% - 5.0% at the extended body board; 4.7% - 15.4% at distance of 1cm from the joint of the extended body board; 0.5% -3.3% at the neck position of the extended board for head,neck and shoulders; 5.3% - 16.7% at the shoulder positions; and 6.8% -30.4% at the joint between the extended boards and the main table board.Conclusions The dose attenuations of the new linear accelerator pure carbon fiber treatment tabletop vary at different locations. Considerable higher attenuations are observed at the table board joints than other locations.

SELECTION OF CITATIONS
SEARCH DETAIL